18 Years Factory Steam Pressure Transmitter Rs485 - Online Conductivity Transmitter With Sensor – JIRS Detail:
Code: BSQ-EC-2019
General introduction
EC/ER/pH/ORP-2019 series transmitter mainly used for the water quality monitor sensor signal output, by 4-20mA, RS485 or TTL, the sensor output weak signal is enlarged to transmit, can be convenient for PLC, configuration software and SCM to communicate by adopting standard communication protocol MODBUS protocol.
EC/ER/pH/ORP series transmitter is widely used in metallurgy manufacturing, power, light industry, textile, water treatment equipment, water pipe network and the scientific research and other industrial sectors.
Transmitter series introduction
Note: A module of the transmitter can only be equipped with one sensor, EC/ER is a module, and PH / ORP is a module.
①: EC conductivity transmitter; range: 0 ~ 4000us / cm, 0-10/20/200mS
②: ER resistivity transmitter; range: 0 ~ 18.2MΩ
③: pH transmitter; range: 0 ~ 14.00 pH
④: ORP redox potential transmitter; range: -2000 ~ + 2000mV
Transmitter series technique specification
No. |
Range |
Matched sensor |
Accuracy |
Connection |
1 |
0.1~18.25MΩ 0.05~10.00uS) |
1:316L S.S. plug into 0.01 sensor 2:Quick install 0.02 sensor; |
2 %FS |
1/2″NPT 1/4”Quick install |
2 |
0.1~200.0uS |
316L S.S. plug-into 0.1 sensor |
|
1/2″NPT) |
3 |
0.5~2000uS(standard) |
ABS1.0 Pt. Black sensor(standard) 316L S.S. plug into 1.0 sensor |
1.5% FS |
1/2″NPT
|
4 |
2~4000uS |
ABS1.0 Pt. Black sensor(standard) 316L S.S. plug into 1.0 sensor |
1.5% FS |
1/2″NPT
|
5 |
0.5~10mS |
ABS1.0 Pt. Black sensor(standard) 316L S.S. plug into 1.0 sensor |
3 % FS |
1/2″NPT
|
6 |
0.5~20mS |
1:316LS.S. plug into10.0 (standard) 2:PTFE+Titanium alloy 10.0 sensor |
1.5 % FS |
1/2″NPT 3/4″NPT |
7 |
0.5~100mS |
1:316LS.S. plug into10.0 (standard) 2:PTFE+Titanium alloy 10.0 sensor |
2 % FS |
1/2″NPT 3/4″NPT |
8 |
0.5~200mS |
PTFE+Titanium alloy 10.0 sensor |
2 % FS |
3/4″NPT |
EC- Conductivity transmitter technique specification,
●Stability: ±2×10-3FS/24h,
●Sensor: 1.0cm-1 constant ABS engineering Plastic Pt. Black sensor, Plug-in or quick-install optional ( other 10.0cm-1 constant sensor optional),
●Sensor threaded size: 1/2″NPT,
●Cable length: Plug-in type standard length is 5m, Quick mounted type is 1.5m,
Measured media temperature:0~50℃,
●Sensor working pressure: 0-0.5Mpa,
●Temperature sensor: NTC 10K,
●Temp. compensation: On basis of 25℃, Auto temp. Compensation.
Other common technique specification,
●Output current: 4~20mA, isolated / Optional:1-5V /2-10V
●Relay output: High/Low limit relay alarm output, Contact point current 24V/3A, 220V/2A ( Passive dry contact)
●Power: DC12V-28V, 24V(Current <=0.1A)
●Environmental conditions: Working temperature:0~50℃, Relative humidity: ≤ 85%RH
●Overall dimension: 122×72×45mm(L x W x H),Installation mode: Cabinet rail installation
Product detail pictures:
Related Product Guide:
Just about every member from our large efficiency income crew values customers' wants and enterprise communication for 18 Years Factory Steam Pressure Transmitter Rs485 - Online Conductivity Transmitter With Sensor – JIRS , The product will supply to all over the world, such as: London, Dominica, Leicester, In order to make more people know our products and to enlarge our market, we have devoted a lot of attention to technical innovations and improvement, as well as replacement of equipment. Last but not the least, we also pay more attention to training our managerial personnel, technicians and workers in planned way.