Factory Outlets Deionized Water Resistivity - Conductivity TDS Controller EC/TDS-6850 – JIRS Detail:
Description
◇ English language display.
◇ Measure Conductivity/TDS/Resistivity and Temperature.
◇ High/low limit relay control output , 4-20mAcurrent output. digital Modbus RS485 communication output (Optional).
◇ High/low limit alarm light, double relay, alarm delay could be set.
◇ Instrument mode isolated transmitting port, max circle resistance up to 750Ω.
◇ PID control to actuate and control powered variable value through 4-20 mA output (optional).
◇ Back light of LCD could select power saving mode, timing automatic off, brightness adjust.
◇ Conductivity constant input directly function or to calibrate probe constant as per known calibration solution’s conductivity value.
◇ High performance CPU, good electromagnetic compatibility.
◇ MOV and AC input be fused function.
◇ ESD over voltage protection is available.
◇ Password management avoid non-professional person to operate.
Main Technique Specifications
Function Model |
EC/TDS/RM-6850 Conductivity /TDS /Resistivity controller |
Measuring Range |
Conductivity: 0-200uS ( 0.1sensor), 0-20, 000uS(1.0 sensor), 0-200mS (10.0 sensor) TDS: 0-100ppm(0.1 sensor), 0-10,000ppm(1.0 sensor) Resistivity: 0-18.25MΩ·cm (0.01 sensor) 0-18250KΩ·cm (0.01 sensor) |
Accuracy |
+ 1.5% (FS) |
Temp. Comp. |
0~120 ℃, Automatic, PT1000 |
Sensor constant |
0.01, 0.1, 1.0, 10.0 cm-1 |
Sensor connection |
1/2”NPT (standard), 3/4”NPT(optional), Flanged (optional) |
Sensor cable length |
5m or as per request |
Display |
128 * 64 dot matrix LCD |
Current output signal |
Isolated, Transferable 4-20mA signal output, max circle resistance 750Ω |
Control output signal |
High/Low Limit relay control output, (3A/250 V AC) |
Communication signal |
Modbus RTU RS485 (optional) |
Power |
AC 220V ±10%, 50Hz (Standard) AC110V ±10%, 50Hz (Optional) AC/DC 24V(optional) |
Working temperature. |
0~60℃, 0~100℃ (Match high temp. Sensor) |
Working pressure |
0~0.5MPa |
Protection grade |
IP 65 |
Working environment |
Ambient Temp. 0~60℃, Relative Humidity ≤95% |
Overall dimensions |
96×96×127mm(high×width×depth) |
Hole dimensions |
92×92mm(height×width) |
Installation Mode |
Panel Mounted(Embeded) |
Application
Widely used for electronic, Chemical, Pharmaceutical, electromechanical, drinking water, cooling tower, boiler plant and other industries for online conductivity, resistivity controller.
Product detail pictures:
Related Product Guide:
abide by the contract", conforms towards the market requirement, joins during the market competition by its good quality likewise as provides additional comprehensive and great services for customers to let them turn out to be big winner. The pursue of your enterprise, is the clients' fulfillment for Factory Outlets Deionized Water Resistivity - Conductivity TDS Controller EC/TDS-6850 – JIRS , The product will supply to all over the world, such as: Sri Lanka, Kuwait, Slovenia, Facing fierce global market competition, we have launched the brand building strategy and updated the spirit of "human-oriented and faithful service", with an aim to gain global recognition and sustainable development.
By Anastasia from Pretoria - 2018.12.25 12:43
As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
By Kevin Ellyson from belarus - 2018.09.29 17:23