Factory Price For 4-20ma Analog Pressure Transmitter - Online ORP transmitter with sensor – JIRS Detail:
Code: BSQ-ORP-2019
General introduction
EC/ER/pH/ORP-2019 series transmitter mainly used for the water quality monitor sensor signal output, by 4-20mA, RS485 or TTL, the sensor output weak signal is enlarged to transmit, can be convenient for PLC, configuration software and SCM to communicate by adopting standard communication protocol MODBUS protocol.
EC/ER/pH/ORP series transmitter is widely used in metallurgy manufacturing, power, light industry, textile, water treatment equipment, water pipe network and the scientific research and other industrial sectors.
Transmitter series introduction
Note: A module of the transmitter can only be equipped with one sensor, EC/ER is a module, and PH / ORP is a module.
①: EC conductivity transmitter; range: 0 ~ 4000us / cm, 0-10/20/200mS
②: ER resistivity transmitter; range: 0 ~ 18.2MΩ
③: pH transmitter; range: 0 ~ 14.00 pH
④: ORP redox potential transmitter; range: -2000 ~ + 2000mV
Transmitter series technique specification
No. |
Range |
Matched sensor |
Accuracy |
Connection |
1 |
0.1~18.25MΩ 0.05~10.00uS) |
1:316L S.S. plug into 0.01 sensor 2:Quick install 0.02 sensor; |
2 %FS |
1/2″NPT 1/4”Quick install |
2 |
0.1~200.0uS |
316L S.S. plug-into 0.1 sensor |
|
1/2″NPT) |
3 |
0.5~2000uS(standard) |
ABS1.0 Pt. Black sensor(standard) 316L S.S. plug into 1.0 sensor |
1.5% FS |
1/2″NPT
|
4 |
2~4000uS |
ABS1.0 Pt. Black sensor(standard) 316L S.S. plug into 1.0 sensor |
1.5% FS |
1/2″NPT
|
5 |
0.5~10mS |
ABS1.0 Pt. Black sensor(standard) 316L S.S. plug into 1.0 sensor |
3 % FS |
1/2″NPT
|
6 |
0.5~20mS |
1:316LS.S. plug into10.0 (standard) 2:PTFE+Titanium alloy 10.0 sensor |
1.5 % FS |
1/2″NPT 3/4″NPT |
7 |
0.5~100mS |
1:316LS.S. plug into10.0 (standard) 2:PTFE+Titanium alloy 10.0 sensor |
2 % FS |
1/2″NPT 3/4″NPT |
8 |
0.5~200mS |
PTFE+Titanium alloy 10.0 sensor |
2 % FS |
3/4″NPT |
ORP- ORP(Redox) transmitter technique specification
Measuring range: -2000~+2000mV
Accuracy:1.0 %(FS)
Stability: ±2×10-3FS/24h
Sensor: online ORP sensor
Sensor threaded size: 3/4″ BSP
Cable length: standard length is 5m,
Measured media temperature:0~100℃
4.6 Other common technique specification
Output current: 4~20mA, isolated / Optional:1-5V /2-10V;
Relay output: High/Low limit relay alarm output, Contact point current 24V/3A, 220V/2A ( Passive dry contact)
Power: DC12V-28V, 24V(Current <=0.1A),
Environmental conditions: Working temperature:0~50℃, Relative humidity: ≤ 85%RH,
Overall dimension: 122×72×45mm(L x W x H),
Installation mode: Cabinet rail installation
Product detail pictures:
Related Product Guide:
To create extra value for customers is our enterprise philosophy; buyer growing is our working chase for Factory Price For 4-20ma Analog Pressure Transmitter - Online ORP transmitter with sensor – JIRS , The product will supply to all over the world, such as: Armenia, Puerto Rico, Liverpool, We have more than 10 years experience of production and export business. We always develop and design kinds of novel products to meet the market demand and help the guests continuously by updating our products. We are specialized manufacturer and exporter in China. Wherever you are, please join us, and together we will shape a bright future in your business field!