Factory source Colorscreen Ro Controller - Conductivity TDS Controller – JIRS Detail:
Description
◇ English language display.
◇ Measure Conductivity/TDS/Resistivity and Temperature.
◇ High/low limit relay control output , 4-20mAcurrent output. digital Modbus RS485 communication output (Optional).
◇ High/low limit alarm light, double relay, alarm delay could be set.
◇ Instrument mode isolated transmitting port, max circle resistance up to 750Ω.
◇ PID control to actuate and control powered variable value through 4-20 mA output (optional).
◇ Back light of LCD could select power saving mode, timing automatic off, brightness adjust.
◇ Conductivity constant input directly function or to calibrate probe constant as per known calibration solution’s conductivity value.
◇ High performance CPU, good electromagnetic compatibility.
◇ MOV and AC input be fused function.
◇ ESD over voltage protection is available.
◇ Password management avoid non-professional person to operate.
Main Technique Specifications
Function Model |
EC/TDS/RM-6850 Conductivity /TDS /Resistivity controller |
Measuring Range |
Conductivity: 0-200uS ( 0.1sensor), 0-20, 000uS(1.0 sensor), 0-200mS (10.0 sensor) TDS: 0-100ppm(0.1 sensor), 0-10,000ppm(1.0 sensor) Resistivity: 0-18.25MΩ·cm (0.01 sensor) 0-18250KΩ·cm (0.01 sensor) |
Accuracy |
+ 1.5% (FS) |
Temp. Comp. |
0~120 ℃, Automatic, PT1000 |
Sensor constant |
0.01, 0.1, 1.0, 10.0 cm-1 |
Sensor connection |
1/2”NPT (standard), 3/4”NPT(optional), Flanged (optional) |
Sensor cable length |
5m or as per request |
Display |
128 * 64 dot matrix LCD |
Current output signal |
Isolated, Transferable 4-20mA signal output, max circle resistance 750Ω |
Control output signal |
High/Low Limit relay control output, (3A/250 V AC) |
Communication signal |
Modbus RTU RS485 (optional) |
Power |
AC 220V ±10%, 50Hz (Standard) AC110V ±10%, 50Hz (Optional) AC/DC 24V(optional) |
Working temperature. |
0~60℃, 0~100℃ (Match high temp. Sensor) |
Working pressure |
0~0.5MPa |
Protection grade |
IP 65 |
Working environment |
Ambient Temp. 0~60℃, Relative Humidity ≤95% |
Overall dimensions |
96×96×127mm(high×width×depth) |
Hole dimensions |
92×92mm(height×width) |
Installation Mode |
Panel Mounted(Embeded) |
Application
Widely used for electronic, Chemical, Pharmaceutical, electromechanical, drinking water, cooling tower, boiler plant and other industries for online conductivity, resistivity controller.
Product detail pictures:
Related Product Guide:
While using the "Client-Oriented" company philosophy, a demanding high-quality management method, innovative producing products and also a sturdy R&D workforce, we always deliver premium quality merchandise, superb solutions and aggressive selling prices for Factory source Colorscreen Ro Controller - Conductivity TDS Controller – JIRS , The product will supply to all over the world, such as: Chile, San Diego, Kazakhstan, They're durable modeling and promoting well all over the world. Under no circumstances disappearing key functions in a brief time, it's a must for yourself personally of fantastic quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the business make an awesome efforts to expand its international trade, raise its enterprise. rofit and improve its export scale. We have been confident that we will have a vibrant prospect and to be distributed all over the world in the years to come.
By Mona from Jordan - 2018.11.28 16:25
A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
By Letitia from Brazil - 2018.06.19 10:42