Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as the theory of "quality the basic, believe in the 1st and management the advanced" for Online Ph Transmitter , Ec Orp Do Transmitter , Lcd Online Radio Transmitter , Normally to the majority of business users and traders to offer best quality goods and excellent company. Warmly welcome to join us, let's innovation collectively, to flying dream.
Factory Supply Tap Water Residual Chlorine - Online Conductivity Transmitter With Sensor – JIRS Detail:

Code: BSQ-EC-2019
General introduction
EC/ER/pH/ORP-2019 series transmitter mainly used for the water quality monitor sensor signal output, by 4-20mA, RS485 or TTL, the sensor output weak signal is enlarged to transmit, can be convenient for PLC, configuration software and SCM to communicate by adopting standard communication protocol MODBUS protocol.

EC/ER/pH/ORP series transmitter is widely used in metallurgy manufacturing, power, light industry, textile, water treatment equipment, water pipe network and the scientific research and other industrial sectors.

Transmitter series introduction
Note: A module of the transmitter can only be equipped with one sensor, EC/ER is a module, and PH / ORP is a module.

①: EC conductivity transmitter; range: 0 ~ 4000us / cm, 0-10/20/200mS
②: ER resistivity transmitter; range: 0 ~ 18.2MΩ
③: pH transmitter; range: 0 ~ 14.00 pH
④: ORP redox potential transmitter; range: -2000 ~ + 2000mV

Transmitter series technique specification

No.

Range

Matched sensor

Accuracy

Connection

1

0.1~18.25MΩ

0.05~10.00uS)

1:316L S.S. plug into 0.01 sensor

2:Quick install 0.02 sensor;

2 %FS

1/2″NPT

1/4”Quick install

2

0.1~200.0uS

316L S.S. plug-into 0.1 sensor

 

1/2″NPT)

3

0.5~2000uS(standard)

ABS1.0 Pt. Black sensor(standard)

316L S.S. plug into 1.0 sensor

1.5% FS

1/2″NPT

 

4

2~4000uS

ABS1.0 Pt. Black sensor(standard)

316L S.S. plug into 1.0 sensor

1.5% FS

1/2″NPT

 

5

0.5~10mS

ABS1.0 Pt. Black sensor(standard)

316L S.S. plug into 1.0 sensor

3 % FS

1/2″NPT

 

6

0.5~20mS

1:316LS.S. plug into10.0 (standard)

2:PTFE+Titanium alloy 10.0 sensor

1.5 % FS

1/2″NPT

3/4″NPT

7

0.5~100mS

1:316LS.S. plug into10.0 (standard)

2:PTFE+Titanium alloy 10.0 sensor

2 % FS

1/2″NPT

3/4″NPT

8

0.5~200mS

PTFE+Titanium alloy 10.0 sensor

2 % FS

3/4″NPT

EC- Conductivity transmitter technique specification,
●Stability: ±2×10-3FS/24h,
●Sensor: 1.0cm-1 constant ABS engineering Plastic Pt. Black sensor, Plug-in or quick-install optional ( other 10.0cm-1 constant sensor optional),
●Sensor threaded size: 1/2″NPT,
●Cable length: Plug-in type standard length is 5m, Quick mounted type is 1.5m,
Measured media temperature:0~50℃,
●Sensor working pressure: 0-0.5Mpa,
●Temperature sensor: NTC 10K,
●Temp. compensation: On basis of 25℃, Auto temp. Compensation.

Other common technique specification,
●Output current: 4~20mA, isolated / Optional:1-5V /2-10V
●Relay output: High/Low limit relay alarm output, Contact point current 24V/3A, 220V/2A ( Passive dry contact)
●Power: DC12V-28V, 24V(Current <=0.1A)
●Environmental conditions: Working temperature:0~50℃, Relative humidity: ≤ 85%RH
●Overall dimension: 122×72×45mm(L x W x H),Installation mode: Cabinet rail installation


Product detail pictures:

Factory Supply Tap Water Residual Chlorine - Online Conductivity Transmitter With Sensor – JIRS detail pictures

Factory Supply Tap Water Residual Chlorine - Online Conductivity Transmitter With Sensor – JIRS detail pictures

Factory Supply Tap Water Residual Chlorine - Online Conductivity Transmitter With Sensor – JIRS detail pictures

Factory Supply Tap Water Residual Chlorine - Online Conductivity Transmitter With Sensor – JIRS detail pictures


Related Product Guide:

To continually enhance the management technique by virtue of your rule of "sincerely, great faith and high-quality are the base of company development", we widely absorb the essence of similar merchandise internationally, and continuously build new merchandise to meet the demands of customers for Factory Supply Tap Water Residual Chlorine - Online Conductivity Transmitter With Sensor – JIRS , The product will supply to all over the world, such as: Uruguay, Pakistan, Bolivia, Our company insists on the principle of "Quality First, Sustainable Development", and takes "Honest Business, Mutual Benefits" as our developable goal. All members sincerely thank all old and new customers' support. We will keep working hard and offering you the highest-quality products and service.
  • The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Wendy from Colombia - 2018.11.06 10:04
    The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Michelle from Victoria - 2017.05.31 13:26
    Write your message here and send it to us