Code: BSQ-PH-2019
Generalis introductio
EC/ER/pH/ORP-2019 series transfusor maxime adhibitus ad aquae qualitatem monitorem sensorem signo output, per 4-20mA, RS485 vel TTL, signum sensorem debile augetur ad transmittendum, opportunum esse potest ad PLC, schematismi configurationis ac SCM communicare adhibendo norma communicationis protocollum MODBUS protocollum.
EC/ER/pH/ORP series transfusor late in fabricatione metallurgia, potentia, levi industria, textili, aqua tractandi instrumento, organo fistulae aquae et investigationi scientifico aliisque sectoribus industrialibus.
Transfusor series introductio
Nota: Modulus transmissionis modo instructus uno
Sensor, EC/ER modulus est, et PH/ORP modulus est.
: EG conductivity transmitter;range: 0 ~ 4000us / cm, 0-10/20/200mS
: ER resistivity transfusor;range: 0 ~ 18.2MΩ
: pH transmitter;range: 0~ 14.00 pH
④: ORP redox potentialis transfusor;range: -2000 ~ + 2000mV
Series transfusoria technica specificatio
Nec. | Range | matched sensorem | Sagacitas | Connection |
1 | 0.1~18.25MΩ 0.05~10.00uS) | 1:316L SS obturaculum in 0.01 sensorem 2:Cito sensorem install 0.02 | 2 %FS | 1/2″NPT 1/4 "Velox install |
2 | 0.1~200.0uS | 316L SS obturaculum-in 0.1 sensorem |
| 1/2″NPT) |
3 | 0.5~2000uS(standard) | ABS1.0 Pt.Sensorem nigrum (vexillum) 316L SS obturaculum in 1.0 sensorem | 1.5% FS | 1/2″NPT
|
4 | 2~4000uS | ABS1.0 Pt.Sensorem nigrum (vexillum) 316L SS obturaculum in 1.0 sensorem | 1.5% FS | 1/2″NPT
|
5 | 0.5~10mS | ABS1.0 Pt.Sensorem nigrum (vexillum) 316L SS obturaculum in 1.0 sensorem | 3% FS | 1/2″NPT
|
6 | 0.5~20mS | 1:316LS.S.obturaculum into10.0 (vexillum) 2:PTFE+Titanium mixturae 10.0 sensorem | 1.5 % FS | 1/2″NPT 3/4″NPT |
7 | 0.5~100mS | 1:316LS.S.obturaculum into10.0 (vexillum) 2:PTFE+Titanium mixturae 10.0 sensorem | 2 % FS | 1/2″NPT 3/4″NPT |
8 | 0.5~200mS | PTFE+ Titanium offensionis 10.0 sensorem | 2 % FS | 3/4″NPT |
PH transfusor technicae artis specificatio
Rhoncus mensurae: 0~14.00;
Accuracy:2.0%(FS);
Stabilitas: ±2×10-3FS/24h;
Sensor: online PH sensorem;
Magnitudo staminea sensoris: 3/4″ BSP;
Cable longitudo: vexillum longitudo est 5m;
Media temperatus metiri: 0~50℃;
Sensorem temperatura: NTC 10K,
Temperatura recompensatio: Ex 25℃, Auto vel Manuale temperatura compensatio;
Modus calibrationis: Tria puncta calibrationis;
PH4.00,PH6.86,PH9.18;
Alia ars communis specificatio
Output current: 4~20mA, solitarius / Libitum: 1-5V /2-10V;
Nullam output: High/low limit Nullam terrorem output, punctum contactus current 24V/3A, 220V/2A (passivum siccum contactum)
Potestas: DC12V-28V, 24V(Current <=0.1A);
Condiciones environmentales: Temperatus Operationis: 0~50℃, humiditas relativa: ≤ 85% RH,
Altiore dimensione: 122×72×45mm(L x W x H);
Modus instruitur: Scrinium rail institutionem