Manufacturing Companies for Online Residual Chlorine Analyzer - Online Conductivity TDS Sensor CR-102S – JIRS

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Gaining purchaser gratification is our firm's intention eternally. We will make wonderful endeavours to build new and top-quality merchandise, satisfy your exclusive needs and provide you with pre-sale, on-sale and after-sale products and services for Joystick Motor Controller , Resistivity And Conductivity Controller , Water Ph Meter Sensor , Our firm quickly grew in size and reputation because of its absolute dedication to superior quality manufacturing, substantial price of solutions and fantastic customer services.
Manufacturing Companies for Online Residual Chlorine Analyzer - Online Conductivity TDS Sensor CR-102S – JIRS Detail:

Pls unpack and check that the sensor has been supplied undamaged and that it is the correct option as ordered. If you have any problems please contact your supplier.

Application
Widely used for industrial water, tap water, cooling water, pure water etc. Conductivity measurement.

Main technique specification

Name

Function

Cell Constant

0.05cm-1  ( v )

0.1cm-1  (  )

1.0cm-1  (  )

10.0cm-1 (  )

Electrode structure

Bipolar

Electrode material

ABS (   )

316L Stainless steel(  v )

Temperature Sensor

NTC 10K ( v )

Pt 1000  (  )

 Pt 100  (  ) 

Thread structure

½” NPT Thread

Working pressure

0~0.5MPa

Operating temperature

0~50℃

Cable length

Standard:5m or others(5-30m)

Dimensions drawing
Conductivity-meter5

Conductivity(TDS)/ Resistivity electrode dimensions 

Installation and maintenance
Installation: To ensure the real measurement result, data distortion caused by air bubble or dead water in conductance cell should be avoided. The installation should be performed strictly according to the following drawing:

Conductivity-meter6

Notes
1. The electrode should be installed at a lower location in the pipe where the flow speed is steady and air bubbles are seldom generated.
2. No matter the conductance cell is horizontally or vertically installed, it should be deeply inserted into the moving water.
3. The conductivity/Resistivity signal is weak electronic signal and its collecting cable should be separately installed.
When threading cable joint or connecting terminal board is used, to avoid wetting interference or breakdown of measurement unit circuit, they should not be connected to the same group of cable joint or terminal board with the power or control line.
4. When the measurement cable needs to be lengthened, it’s recommended to use the cable provided by the original manufacturer, and the joint should be subject to reliable damp-proofing insulation disposal. When a longer distance is involved, the length of the cable (<30m) should be agreed on before delivery, and if the length is over 30m, a transmitter should be used.

Electrode Maintenance
1. The electrode cell should not be soaked in strong acid or alkali liquid, and the platinum black coating should not be wiped or it will lead to electrode surface damage and the constant and response capability will be affected. The right way should be: when the electrode is dirty, soak it in 10% dilute hydrochloric acid for a short while, then rinse it with pure water to keep the surface clean.
2. The measurement cable is special cable and should not be changed at will or it will cause significant error.

Joint wire
white wire to Cell -INPUT
Yellow wire to Cell -OUPUT
Black wire-TEMP
Red wire-TEMP

JiShen Water treatment Co., Ltd.
Add: No.18, Xingong Road, High-Technology Area, Shijiazhuang,China
Tel: 0086-(0)311-8994 7497 Fax:(0)311-8886 2036
E-mail:info@watequipment.com
Website: www.watequipment.com


Product detail pictures:

Manufacturing Companies for Online Residual Chlorine Analyzer - Online Conductivity TDS Sensor CR-102S – JIRS detail pictures

Manufacturing Companies for Online Residual Chlorine Analyzer - Online Conductivity TDS Sensor CR-102S – JIRS detail pictures

Manufacturing Companies for Online Residual Chlorine Analyzer - Online Conductivity TDS Sensor CR-102S – JIRS detail pictures


Related Product Guide:

As a way to present you with ease and enlarge our enterprise, we also have inspectors in QC Workforce and assure you our greatest support and solution for Manufacturing Companies for Online Residual Chlorine Analyzer - Online Conductivity TDS Sensor CR-102S – JIRS , The product will supply to all over the world, such as: Mauritius, Zambia, Guyana, During in 11 years,We have participated in more than 20 exhibitions,obtains the highest praise from each customer. Our company always aim to provide the customer best products with lowest price. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us. Join us, show your beauty. We will always be your first choice. Trust us, you will never lose heart.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Vanessa from Detroit - 2017.08.18 11:04
    In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By May from Iraq - 2017.08.28 16:02
    Write your message here and send it to us