Short Lead Time for Conductivity Ro Controller - Conductivity TDS Controller – JIRS Detail:
Description
◇ English language display.
◇ Measure Conductivity/TDS/Resistivity and Temperature.
◇ High/low limit relay control output , 4-20mAcurrent output. digital Modbus RS485 communication output (Optional).
◇ High/low limit alarm light, double relay, alarm delay could be set.
◇ Instrument mode isolated transmitting port, max circle resistance up to 750Ω.
◇ PID control to actuate and control powered variable value through 4-20 mA output (optional).
◇ Back light of LCD could select power saving mode, timing automatic off, brightness adjust.
◇ Conductivity constant input directly function or to calibrate probe constant as per known calibration solution’s conductivity value.
◇ High performance CPU, good electromagnetic compatibility.
◇ MOV and AC input be fused function.
◇ ESD over voltage protection is available.
◇ Password management avoid non-professional person to operate.
Main Technique Specifications
Function Model |
EC/TDS/RM-6850 Conductivity /TDS /Resistivity controller |
Measuring Range |
Conductivity: 0-200uS ( 0.1sensor), 0-20, 000uS(1.0 sensor), 0-200mS (10.0 sensor) TDS: 0-100ppm(0.1 sensor), 0-10,000ppm(1.0 sensor) Resistivity: 0-18.25MΩ·cm (0.01 sensor) 0-18250KΩ·cm (0.01 sensor) |
Accuracy |
+ 1.5% (FS) |
Temp. Comp. |
0~120 ℃, Automatic, PT1000 |
Sensor constant |
0.01, 0.1, 1.0, 10.0 cm-1 |
Sensor connection |
1/2”NPT (standard), 3/4”NPT(optional), Flanged (optional) |
Sensor cable length |
5m or as per request |
Display |
128 * 64 dot matrix LCD |
Current output signal |
Isolated, Transferable 4-20mA signal output, max circle resistance 750Ω |
Control output signal |
High/Low Limit relay control output, (3A/250 V AC) |
Communication signal |
Modbus RTU RS485 (optional) |
Power |
AC 220V ±10%, 50Hz (Standard) AC110V ±10%, 50Hz (Optional) AC/DC 24V(optional) |
Working temperature. |
0~60℃, 0~100℃ (Match high temp. Sensor) |
Working pressure |
0~0.5MPa |
Protection grade |
IP 65 |
Working environment |
Ambient Temp. 0~60℃, Relative Humidity ≤95% |
Overall dimensions |
96×96×127mm(high×width×depth) |
Hole dimensions |
92×92mm(height×width) |
Installation Mode |
Panel Mounted(Embeded) |
Application
Widely used for electronic, Chemical, Pharmaceutical, electromechanical, drinking water, cooling tower, boiler plant and other industries for online conductivity, resistivity controller.
Product detail pictures:
Related Product Guide:
"Quality very first, Honesty as base, Sincere assistance and mutual profit" is our idea, in an effort to create consistently and pursue the excellence for Short Lead Time for Conductivity Ro Controller - Conductivity TDS Controller – JIRS , The product will supply to all over the world, such as: Jeddah, kazakhstan, Bangalore, Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective solutions and meticulous after-sales service. We firmly believe that: we're outstanding as we have been specialized.
By Eartha from Malta - 2018.12.22 12:52
We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
By Laurel from Egypt - 2017.08.21 14:13