Short Lead Time for On Line Residual Chlorine Controller - Online Conductivity TDS Sensor – JIRS Detail:
Pls unpack and check that the sensor has been supplied undamaged and that it is the correct option as ordered. If you have any problems please contact your supplier.
Application
Widely used for industrial water, tap water, cooling water, pure water etc. Conductivity measurement.
Main technique specification
Name |
Function |
Cell Constant |
0.05cm-1 ( v ) 0.1cm-1 ( ) 1.0cm-1 ( ) 10.0cm-1 ( ) |
Electrode structure |
Bipolar |
Electrode material |
ABS ( ) 316L Stainless steel( v ) |
Temperature Sensor |
NTC 10K ( v ) Pt 1000 ( ) Pt 100 ( ) |
Thread structure |
½” NPT Thread |
Working pressure |
0~0.5MPa |
Operating temperature |
0~50℃ |
Cable length |
Standard:5m or others(5-30m) |
Dimensions drawing
Conductivity(TDS)/ Resistivity electrode dimensions
Installation and maintenance
Installation: To ensure the real measurement result, data distortion caused by air bubble or dead water in conductance cell should be avoided. The installation should be performed strictly according to the following drawing:
Notes
1. The electrode should be installed at a lower location in the pipe where the flow speed is steady and air bubbles are seldom generated.
2. No matter the conductance cell is horizontally or vertically installed, it should be deeply inserted into the moving water.
3. The conductivity/Resistivity signal is weak electronic signal and its collecting cable should be separately installed.
When threading cable joint or connecting terminal board is used, to avoid wetting interference or breakdown of measurement unit circuit, they should not be connected to the same group of cable joint or terminal board with the power or control line.
4. When the measurement cable needs to be lengthened, it’s recommended to use the cable provided by the original manufacturer, and the joint should be subject to reliable damp-proofing insulation disposal. When a longer distance is involved, the length of the cable (<30m) should be agreed on before delivery, and if the length is over 30m, a transmitter should be used.
Electrode Maintenance
1. The electrode cell should not be soaked in strong acid or alkali liquid, and the platinum black coating should not be wiped or it will lead to electrode surface damage and the constant and response capability will be affected. The right way should be: when the electrode is dirty, soak it in 10% dilute hydrochloric acid for a short while, then rinse it with pure water to keep the surface clean.
2. The measurement cable is special cable and should not be changed at will or it will cause significant error.
Joint wire
white wire to Cell -INPUT
Yellow wire to Cell -OUPUT
Black wire-TEMP
Red wire-TEMP
JiShen Water treatment Co., Ltd.
Add: No.18, Xingong Road, High-Technology Area, Shijiazhuang,China
Tel: 0086-(0)311-8994 7497 Fax:(0)311-8886 2036
E-mail:info@watequipment.com
Website: www.watequipment.com
Product detail pictures:
Related Product Guide:
Gaining client pleasure is our company's aim without end. We are going to make excellent efforts to create new and top-quality goods, meet your special requirements and provide you with pre-sale, on-sale and after-sale companies for Short Lead Time for On Line Residual Chlorine Controller - Online Conductivity TDS Sensor – JIRS , The product will supply to all over the world, such as: Bolivia, Argentina, Gabon, We have been very responsible for all details on our customers order no matter on warranty quality, satisfied prices, quick delivery, on time communication, satisfied packing, easy payment terms, best shipment terms, after sales service etc. We provide one-stop service and best reliability to our every customers. We work hard with our customers, colleagues, workers to make a better future.